How temperature of job of oily fluid of conduction oil furnace decides and the requirement to using

Conduction oil furnace, this is boiler one specific with common sort, and can say application is wide, have the necessity that learn and understands so, so, be based on this, next, it is to be conduction oil furnace of relevant knowledge explain, or the solution that is a few common problems, good let everybody have study content, then, can deepen oneself to be opposite conduction oil furnace the familiar degree of this kind of boiler.

 

1.Be in high temperature to run the conduction oil furnace of condition, encounter unexpected power failure should be this one circumstance handled how correctly?

Be in high temperature to run the conduction oil furnace of condition, if encounter power cut,this breaks out a circumstance, his correct processing is:

 

When circular oil pump cannot run normally because of power cut, furnace is in charge of the conduction oil inside, because of the chamber of a stove or furnace its temperature meets more than hot action allow a value more than inside short time, at this moment, should open cold oil to change valve, will expand to the cold oil inside groove is released and send toInside lay aside oil groove. In the meantime, undertakeWet coal banking fire or urgent processing stopping furnace, need to be inFinish inside 5 minutes.

In addition, what we need to notice is, will not expand the oil inside groove is put clean, otherwise, the system is met induction air and occurrence problem. Can be inFluid of lay aside oil groove go up one oily fluid mark, when undertaking cold oily displacement, can close this valve in time and avoidExpand grooveAndLay asideOil groove is put empty.

 

2.By what the working temperature of conduction oil is decided? Is size of its difference in temperature right is conduction oil furnace influential?

The working temperature of conduction oil, will tell from professional point of view, be by be heated in the equipment that use heat the temperature that stock place needs will decide. Will tell commonly, it is to ask prep above of temperature of the conduction oil in conduction oil furnace is heated the temperature of stock, what and difference in temperature is jumped over need greatly heat the area is smaller. Nevertheless, to some stock, if be in high temperature condition to fall, meeting occurrence problem. So, size of difference in temperature can produce an effect to stock, but to conduction oil furnace, be being affected is not very big.

 

3.Conduction oil furnaceWhether does personnel have a demand with use unit to the operation?

Conduction oil furnace is mixed to operation personnel use unit, have a few demands, its are specific if tell, it is to be: On operation personnel, it is to ask to undertake a few major groom, wantVia local boiler safety censorial orgnaization assessment sends card. To using an unit, it is the operating rules that should make conduction oil oven, operation personnel operates boiler according to this one operating rules, forbidden violate compasses operation.