Conduction oil furnace stops pump to want note of component of sue for peace to conduction oil

Conduction oil furnace, its are one of boiler, and or main product is mixed in the website advocate hit one of keywords, the study that should take this product seriously so works, cannot have the least bit and careless and lax, in the meantime, will in time master its relevant knowledge, in so that the study sth in order to apply it of implementation knowledge is mixed,working actually apply neatly, then, good use result is achieved on the use of this product.

 

1.Is the conduction oil in conduction oil furnace main?

The conduction oil in conduction oil furnace, its are a very important part, and if conduction oil appears problem, so, be be used what can affect boiler normally and move, then, affect the use result of boiler. So, should give take seriously, and, returning what need knows is, microtherm conduction oil should undertake dehydration works, otherwise the moisture transgression in conduction oil can bring about boiler pressure occurrence wave motion, then, occurrence problem.

 

2.Why after conduction oil furnace stops pump, has conduction oil to flow? Whether can a few earlier stop pump?

After conduction oil furnace stops pump, conduction oil cannot not flow in heating furnace, because if word of conduction oil stagnant, the quantity of heat in heating furnace can make conduction oil temperature elevatory, if exceed,bear oilily the limit, can shorten oily service life, and, return influence of can normal to boiler moving generation. In addition, conduction oil furnace also cannot stop pump prematurely, this meeting makes conduction oil degenerative.

 

3.Chamfer of perch of conduction oil furnace and oil gas segregator, whether to have a note?

The exalted chamfer in conduction oil furnace and oil gas segregator these two components, have a few notes, its are main, it is exalted chamfer height cannot pass low, and dimension of norms of oil gas segregator also cannot too small, otherwise, can make exalted chamfer thermal drop does not come down, then, conduction oil is oxidized, affect the coefficient of thermal conductivity of conduction oil furnace. In addition, this boiler the chamber of a stove or furnace also can appear knot anxious problem.

 

4.What standard to should conduction oil furnace consult and implement? Whether can be two conduction oil furnace used?

Conduction oil furnace this kind of boiler, the standard that its should consult and implements, it is to beTSG G0001-2012 " boiler security technology is censorial regulations "AndSY/T 0524-2008 " standard of system of conduction oil heating furnace "These two. In addition, two conduction oil furnace can be used, it is one equipment is used commonly. The welding line of conduit joint, want to make sure quality is eligible.