How does installation reach more than heat boiler and incinerator boiler is important payoff

The more than heat boiler in boiler believes everybody won't feel unfamiliar one kind this, because undertaking this kind of boiler all the time in the website of relevant knowledge explain the job, or the solution that is its difficulty problem, good let everybody have study object and study content, then, will have comprehensive understanding and knowledge to more than heat boiler. So, next, still have this job, good the learning process that pushs product of this one website, let everybody amount to mark as soon as possible.

 

1.The conduction oil furnace of 20 million kilocalorie, the more than heat boiler that how many tonnage configures are its?

Will tell commonly, the conduction oil furnace of 6 million kilocalorie, its use tail gas to be able to produce 1 ton of steam, so, it is the more than heat boiler that configures 1 ton, and the conduction oil furnace of 20 million kilocalorie, the tonnage of the more than heat boiler that its choose, it is to be 3 go to 3.5 tons, say so, the conduction oil furnace of this one calorific value, it is to configure the 3 more than heat boiler to 3.5 tons.

 

2.Incinerator and between more than heat boiler, whether should have certain space? More than heat boiler uses pure low temperature more than heat generates electricity, how much is its boiler pressure?

Incinerator and more than heat boiler, these two should be together repeatedly, should not have any spaces, because more than heat boiler is to leanThe exhaust quantity of heat of incineratorWill drive have the job, undertake be usinged effectively to more than heat, can reduce moving cost so. If if more than heat boiler uses pure low temperature,more than heat generates electricity, its boiler pressure is to have1MPa, 1.25MPa, 1.6MPa, 2MPa and 2.5MPa these 5.

 

3.More than heat boilerIn, want temperature of prep above dew point for temperature of how smoke evacuation? In addition, this boiler weight and what are concerned?

In more than heat boiler, temperature of its smoke evacuation wants the account of temperature of prep above dew point, because,be if smoke evacuation temperature the word under dew point temperature, the acidity gas experience in flue gas condenses in boiler rear flue, bring about flue rear occurrence acidity to corrode, then, shorten badly the service life of boiler.

 

The weight of more than heat boiler, its basically are with waste gas the entrance and outlet temperature are concerned, and, temperature of waste gas entrance is higher, criterion unit ton the boiler weight of evaporate is less. In addition, waste gas outlet temperature is lower, criterion boiler weight is greater. If waste gas temperature is to be700 go to 800 degrees, weight of more than heat boiler is to be 1000 tons or so.