Hot water boiler opens regulation stopping furnace measure and which kind of need blowdown
The hot water boiler in boiler this kind, product of its since website is website keyword, so, be necessary to undertake be familiar with and understanding, should achieve comprehensive this one degree, such ability implementation are used correctly of this product and reasonable use, then, will have good economic benefits, in the meantime, everybody some are harvested and also can inspire from which.
1.29MWHot water boiler, how many tons hot water boiler are its equivalent to?
Hot water boiler, if its are29MWIf, show the ability of rated heat addition of this boiler, it is to be29 million are made of baked clay / hour, press every0.7MwApproximate1 ton of this one standard comes the word of conversion, 29MW is equivalent to40 tons, so, 29MWHot water boiler, its are equivalent to40 tons hot water boiler, nevertheless, this is one estimation value only.
2.Of hot water boiler start and stop furnace, whether to have formulary move?
Of hot water boiler start and stop furnace, its have formulary move. When boiler is started, it is pump of moving sex loop above all, ignite burner again, and boiler stops furnace, it is to stop burner first, circular pump stops again after moving period of time. Nevertheless, on mode of operation, traditional is the hand moves an operation, develop ceaselessly as the technology and progress, can have realized computer control to move, will replace a hand to move an operation. And, it is OK that its operate measure good by program set, also can prevent wrong operation so.
3.Often be pressed and vacuum and hot water boiler, which needs blowdown?
In hot water boiler often press boiler and vacuum boiler, boiler needs to undertake blowdown is operated in moving process, be to often press hot water boiler, boiler of vacuum hot water does not need to have this job, because: Often press hot water boiler, methodical water enters boiler in, and boiler heats high temperature water, after systematic filling water passes the processing of soft water equipment, can the major calcium in purify water and magnesian ion, but in still a few meetings enter boiler. So, after calcium and magnesian ion reach certain consistency, need undertakes blowdown is operated, lest exist ionicly as a result of these, bring about boiler to run occurrence problem.
4.If knew the nominal working pressure of hot water boiler, what how decide relief valve is whole calm pressure limits?
Hot water boiler, if knew its nominal working pressure, so, be can make calm pressure range with what will decide relief valve, its are worth floor level to go up in pressure, it is to take the actuating pressure of 1.1 times, but cannot be less than actuating pressure to add 0.07MPa. On pressure limits upper limit, it is to take the actuating pressure of 1.2 times, but cannot be less than actuating pressure to add 0.1MPa.