Configuration of fan of coal fired steam boiler and real cost coal measure computational condition
On the specific sort of boiler, what below the meeting in explaining involves is phyletic, it is to beCoal fired steam boiler, its can consider as belong to coal fired boiler, and it is coal fired boiler one common with commonly used sort. And, it is in website product, so, be based on this at 2 o'clock, answer this kind of boiler to have comprehensive understanding and knowledge, such ability come true to be used correctly of this product, so that come,obtain good use effect and economic benefits.
1. 20 tons coal fired steam boiler, its everyday the quantity that use coal, how much be to be on theoretical value?
20 tons coal fired steam boiler, its go up in the computation that measures with coal everyday, if be theoretical value, it is to need to know a few boiler are specific parameter, such abilities get particular numerical value through computation, cannot give out otherwise. If, this boiler is rated vapour pressure is to be 1MPa, coal calorific value is to be7000 kilocalorie / kilogram, boiler takes water temperature is to be20 ℃, boiler efficiency is to be90% , so, its are measured with coal everyday is to be 50, 56 tons.
2. 2 tons coal fired steam boiler, want to get real cost coal is measured, what should know?
2 tons coal fired steam boiler, if wanting to get actually coal of time waste time is measured, so, it is to should know steam boiler of 2 tons of coal fired has bodily form number, and coal fired is specific and phyletic, such ability will undertake correctly computational working, and at the same time, also can get accurate result. And, on this, everybody is due and correct understanding, such ability avoid to make mistake.
3. In 1 ton coal fired steam boiler, whether to bring fan and air-blower from time to tome together?
In 1 ton coal fired steam boiler, whether do its have already bring fan to have air-blower again, will tell from professional point of view, it is to be not configured bring fan, configure air-blower only. Because this is to be commonly,often press boiler, and and boiler water capacity is not very big, so, do not need to be used bring fan.
4. Coal fired steam boiler, the reference standard of its thermal efficiency, which be? In addition, its are less thanAn evaporate ton if, how much is thermal efficiency to be?
Coal fired steam boiler, the reference standard of its thermal efficiency, it is to beTSG G0002-2010The appendix in this one standardThe regulation of A. And this kind of boiler, if be less than an evaporate ton if, so, boiler efficiency is to be 73% , 79% . So, on this, cannot make mistake, lest the influence is used to the operation of boiler,wait for these respects.